| Assessment Year | 1995 |
|---|---|
| Principal Product | Custom Metal Stamping and Vending Machines |
| NAICS |
n/a
|
| SIC | 3469: Metal Stampings, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
270,000
ft2
|
| Annual Production | 10,000
pieces
|
| Production Hrs. Annual | 6,883
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $278,879 | 5,355,510 |
kWh
|
$0.052 |
| Natural Gas | $206,854 | 69,546 |
MMBtu
|
$2.97 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $78,302 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $76,606 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Ancillary Material Cost Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,396 | $1,564 |
$4,396
73,857
kWh
|
- | - | - | - | |
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $2,300 | $2,790 |
$2,300
45,135
kWh
|
- | - | - | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $2,536 | $5,120 |
$2,536
44,256
kWh
|
- | - | - | - | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $968 | - |
$968
12,603
kWh
|
- | - | - | - | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $1,166 | $200 |
$1,166
24,619
kWh
|
- | - | - | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,401 | $300 |
$11,401
241,208
kWh
|
- | - | - | - | |
| 07 | 2.1116: Improve combustion control capability | $53,202 | $25,000 | - |
$53,202
-
MMBtu
|
- | - | - | |
| 08 | 3.4151: Minimize water usage | $637 | $125 | - | - |
$328
-
Tgal
|
- |
$309
-
Tgal
|
|
| 09 | 3.8314: Purchase high materials in returnable bulk containers | $1,696 | - | - | - | - | $1,696 | - | |
| TOTAL RECOMMENDED | $78,302 | $35,099 |
$22,767
441,678
kWh
|
$53,202
-
MMBtu
|
$328
-
Tgal
|
$1,696 |
$309
-
Tgal
|
||
| TOTAL IMPLEMENTED | $76,606 | $35,099 |
$22,767
441,678
kWh
|
$53,202
-
MMBtu
|
$328
-
Tgal
|
- |
$309
-
Tgal
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Water Disposal Savings | Ancillary Material Cost Savings | Water Consumption Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs