| Assessment Year | 1995 |
|---|---|
| Principal Product | Paper Coating |
| NAICS |
n/a
|
| SIC | 2671: Packaging Paper and Plastics Film, Coated and Laminated |
| Sales Range | $1 M to 5M |
| # of Employees | 70 |
| Plant Area |
300,000
ft2
|
| Annual Production | 36,000,000
lb
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $298,580 | 5,109,906 |
kWh
|
$0.058 |
| Natural Gas | $14,642 | 2,947 |
MMBtu
|
$4.97 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $32,632 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $22,467 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,115 | $554 |
$3,115
53,634
kWh
|
|
| 02 | 2.7111: Reduce illumination to minimum necessary levels | $13,187 | $3,130 |
$13,187
230,950
kWh
|
|
| 03 | 2.4133: Use most efficient type of electric motors | $3,258 | $3,820 |
$3,258
56,272
kWh
|
|
| 04 | 2.3212: Optimize plant power factor | $2,940 | $7,020 |
$2,940
-
kWh
|
|
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $623 | - |
$623
10,844
kWh
|
|
| 06 | 2.4221: Install compressor air intakes in coolest locations | $1,288 | $200 |
$1,288
22,860
kWh
|
|
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $996 | $300 |
$996
17,585
kWh
|
|
| 08 | 2.2511: Insulate bare equipment | $7,225 | $210 |
$7,225
123,681
kWh
|
|
| TOTAL RECOMMENDED | $32,632 | $15,234 |
$32,632
515,826
kWh
|
||
| TOTAL IMPLEMENTED | $22,467 | $8,004 |
$22,467
392,145
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs