Assessment Year | 1994 |
---|---|
Principal Product | Processed Turkeys |
NAICS |
n/a
|
SIC | 2015: Poultry Slaughtering and Processing |
Sales Range | $10 M to 50M |
# of Employees | 490 |
Plant Area |
100,000
ft2
|
Annual Production | 117,000,000
lb
|
Production Hrs. Annual | 4,171
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,511,133 | 27,473,623 |
kWh
|
$0.055 |
Natural Gas | $32,381 | 11,671 |
MMBtu
|
$2.77 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $82,262 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $82,262 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $1,273 | $250 |
$1,273
23,154
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,679 | $887 |
$1,679
30,481
kWh
|
- | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $1,921 | $870 |
$1,921
34,877
kWh
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $3,622 | $4,610 |
$3,622
65,944
kWh
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $770 | $456 |
$770
14,068
kWh
|
- | |
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $56,477 | $1,000 | - |
$56,477
-
MMBtu
|
|
07 | 2.2135: Repair and eliminate steam leaks | $16,520 | $1,000 | - |
$16,520
-
MMBtu
|
|
TOTAL RECOMMENDED | $82,262 | $9,073 |
$9,265
168,524
kWh
|
$72,997
-
MMBtu
|
||
TOTAL IMPLEMENTED | $82,262 | $9,073 |
$9,265
168,524
kWh
|
$72,997
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs