ITAC Assessment: AR0033
ITAC logo
ITAC Assessment: AR0033
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1994
Principal Product Wood Furniture
NAICS
n/a
SIC 2426: Hardwood Dimension and Flooring Mills
Sales Range $50
M
to 100
M
# of Employees 698
Plant Area 200,000
ft2
Annual Production 341,500
pieces
Production Hrs. Annual 6,257
hrs
Location (State) Arkansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $605,246 15,396,249
kWh
Natural Gas $148,605 43,614
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $22,229 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $27,229

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Personnel Changes Savings
01 2.4221: Install compressor air intakes in coolest locations $2,144 $750 $2,144
55,100
kWh
- -
02 2.4133: Use most efficient type of electric motors $5,939 $8,697 $5,939
152,989
kWh
- -
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $847 $753 $847
21,395
kWh
- -
04 2.4134: Replace electric motor with fossil fuel engine $(-5,000.0) $30,000 $27,547
715,123
kWh
$(-27,547.0)
-
MMBtu
$(-5,000.0)
05 2.7142: Utilize higher efficiency lamps and/or ballasts $8,903 $4,477 $8,903
227,433
kWh
- -
06 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $6,412 $550 $6,412
165,299
kWh
- -
07 2.2437: Recover waste heat from equipment $1,255 $500 - $1,255
-
MMBtu
-
08 2.7124: Make a practice of turning off lights when not needed $1,729 $100 $1,729
41,325
kWh
- -
TOTAL RECOMMENDED $22,229 $45,827 $53,521
1,378,664
kWh
$(-26,292.0)
-
MMBtu
$(-5,000.0)
TOTAL IMPLEMENTED $27,229 $15,827 $25,974
663,541
kWh
$1,255
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs