Assessment Year | 1994 |
---|---|
Principal Product | Boilers |
NAICS |
n/a
|
SIC | 3440: |
Sales Range | $10 M to 50M |
# of Employees | 300 |
Plant Area |
146,739
ft2
|
Annual Production | 500
ton
|
Production Hrs. Annual | 5,214
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $169,385 | 2,439,918 |
kWh
|
$0.069 |
Natural Gas | $63,512 | 15,051 |
MMBtu
|
$4.22 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $52,696 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $52,696 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $16,260 | $6,000 |
$16,260
-
kWh
|
|
02 | 2.2515: Use optimum thickness insulation | $855 | $100 |
$855
12,309
kWh
|
|
03 | 2.3212: Optimize plant power factor | $20,139 | $9,600 |
$20,139
-
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,558 | $150 |
$1,558
22,567
kWh
|
|
05 | 2.3512: De-energize excess transformer capacity | $3,017 | $5,760 |
$3,017
19,930
kWh
|
|
06 | 2.4221: Install compressor air intakes in coolest locations | $794 | $300 |
$794
11,430
kWh
|
|
07 | 2.7111: Reduce illumination to minimum necessary levels | $6,740 | $790 |
$6,740
97,011
kWh
|
|
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,386 | $822 |
$1,386
19,930
kWh
|
|
09 | 2.6218: Turn off equipment when not in use | $1,947 | - |
$1,947
28,136
kWh
|
|
TOTAL RECOMMENDED | $52,696 | $23,522 |
$52,696
211,313
kWh
|
||
TOTAL IMPLEMENTED | $52,696 | $23,522 |
$52,696
211,313
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs