Assessment Year | 1994 |
---|---|
Principal Product | Fluid Milk |
NAICS |
n/a
|
SIC | 2026: Fluid Milk |
Sales Range | $10 M to 50M |
# of Employees | 250 |
Plant Area |
78,900
ft2
|
Annual Production | 22,000
Tgal
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $602,844 | 9,160,024 |
kWh
|
$0.066 |
Natural Gas | $113,460 | 39,262 |
MMBtu
|
$2.89 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $165,952 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $52,339 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $34,041 | $3,140 |
$34,041
517,292
kWh
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $7,002 | $988 |
$7,002
106,389
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $6,208 | $9,070 |
$6,208
94,373
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $1,786 | $100 |
$1,786
27,257
kWh
|
- | |
05 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $113,613 | $70,000 |
$147,976
2,248,242
kWh
|
$(-34,363.0)
-
MMBtu
|
|
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,302 | $802 |
$3,302
50,117
kWh
|
- | |
TOTAL RECOMMENDED | $165,952 | $84,100 |
$200,315
3,043,670
kWh
|
$(-34,363.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | $52,339 | $14,100 |
$52,339
795,428
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs