| Assessment Year | 2025 |
|---|---|
| Principal Product | Pre-engineered metal building components |
| NAICS | 332311: Prefabricated Metal Building and Component Manufacturing |
| SIC | 3448: Prefabricated Metal Buildings and Components |
| Sales Range | $50 M to 100M |
| # of Employees | 226 |
| Plant Area |
480,000
ft2
|
| Annual Production | 27,000
ton
|
| Production Hrs. Annual | 7,344
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $291,839 | 4,318,129 |
kWh
|
$0.068 |
| Electricity Demand | $163,333 | 17,175 |
kW-mo/yr
|
$9.51 |
| Electricity Fees | $37,450 | - |
|
- |
| Natural Gas | $72,040 | 11,988 |
MMBtu
|
$6.01 |
| TOTAL YEARLY COSTS | $564,662 | |||
| RECOMMENDED SAVINGS* | $190,072 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $118,795 | $20,000 | - | - | $26,695 | $3,000 | $89,100 | |
| 02 | 2.3212: Optimize plant power factor | $12,900 | $36,800 | - |
$12,900
-
kW-mo/yr
|
- | - | - | |
| 03 | 3.1191: Change procedures / equipment / operating conditions | $13,100 | $55,700 |
$13,100
193,000
kWh
|
- | - | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $765 | $188 |
$623
9,160
kWh
|
$142
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.4224: Upgrade controls on compressors | $3,112 | $36,750 |
$2,210
32,500
kWh
|
$902
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.9114: Use solar heat to make electricty | $41,400 | $835,300 |
$41,400
609,000
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $190,072 | $984,738 |
$57,333
843,660
kWh
|
$13,944
-
kW-mo/yr
|
$26,695 | $3,000 | $89,100 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs