Assessment Year 2025
Principal Product severe service ball valves and automation
NAICS 333911: Pump and Pumping Equipment Manufacturing
SIC 3561: Pumps and Pumping Equipment
Sales Range $10
M
to 50
M
# of Employees 160
Plant Area 75,500
ft2
Annual Production 50,000
units
Production Hrs. Annual 4,165
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $269,747 5,927,198
kWh
Electricity Demand $182,976 19,653
kW-mo/yr
Electricity Fees $40,526 -
Natural Gas $13,128 1,428
MMBtu
TOTAL YEARLY COSTS $506,376
RECOMMENDED SAVINGS* $292,251 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings
01 2.9114: Use solar heat to make electricty $93,065 $1,113,790 $93,065
1,751,873
kWh
- - -
02 2.8121: Apply for tax-free status for energy purchases $147,920 $15,000 - - $36,980 $110,940
03 2.4239: Eliminate or reduce compressed air usage $22,554 $2,925 $22,554
490,300
kWh
- - -
04 2.3212: Optimize plant power factor $14,370 $29,250 - $14,370
-
kW-mo/yr
- -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $11,153 $1,000 $10,473
227,672
kWh
$680
-
kW-mo/yr
- -
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,280 $2,129 $234
5,084
kWh
$2,046
-
kW-mo/yr
- -
07 2.4221: Install compressor air intakes in coolest locations $909 $1,080 $537
11,680
kWh
$372
-
kW-mo/yr
- -
TOTAL RECOMMENDED $292,251 $1,165,173 $126,863
2,486,609
kWh
$17,468
-
kW-mo/yr
$36,980 $110,940
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings One-time Revenue or Avoided Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs