Assessment Year 2023
Principal Product Treated wastewater
NAICS 221320: Sewage Treatment Facilities
SIC 4952: Sewerage Systems
Sales Range $5
M
to 10
M
# of Employees 2
Plant Area 590,000
ft2
Annual Production 109,500
Tgal
Production Hrs. Annual 8,760
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $148,101 3,901,398
kWh
Electricity Demand $55,871 7,089
kW-mo/yr
Electricity Fees $5,685 -
TOTAL YEARLY COSTS $209,657
RECOMMENDED SAVINGS* $27,698 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $8,563

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings
01 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary $16,120 $700 $16,120
435,560
kWh
- -
02 2.4156: Establish a preventative maintenance program $6,607 $4,020 $1,848
49,956
kWh
$3,901
-
kW-mo/yr
$858
03 2.3212: Optimize plant power factor $3,015 $16,615 - $3,015
-
kW-mo/yr
-
04 2.4111: Utilize energy-efficient belts and other improved mechanisms $780 - $560
15,130
kWh
$220
-
kW-mo/yr
-
05 2.4133: Use most efficient type of electric motors $630 $3,605 $470
12,800
kWh
$160
-
kW-mo/yr
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $510 $2,441 $688
18,602
kWh
- $(-178.0)
07 2.7124: Make a practice of turning off lights when not needed $36 $18 $20
525
kWh
$16
-
kW-mo/yr
-
TOTAL RECOMMENDED $27,698 $27,399 $19,706
532,573
kWh
$7,312
-
kW-mo/yr
$680
TOTAL IMPLEMENTED $8,563 $10,084 $3,586
97,013
kWh
$4,297
-
kW-mo/yr
$680
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs