Assessment Year | 2021 |
---|---|
Principal Product | Sanitized wastewater |
NAICS | 221320: Sewage Treatment Facilities |
SIC | 4952: Sewerage Systems |
Sales Range | $1 M to 5M |
# of Employees | 10 |
Plant Area |
5,000
ft2
|
Annual Production | 2,920
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $114,511 | 3,098,014 |
kWh
|
$0.037 | |
Electricity Demand | $104,579 | 8,119 |
kW-mo/yr
|
$12.88 | |
Electricity Fees | $448 | - |
|
- | |
Waste Disposal Costs | |||||
Water Usage | $31,766 | 12,863 |
Tgal
|
$2.47 | |
TOTAL YEARLY COSTS | $251,304 | ||||
RECOMMENDED SAVINGS* | $39,295 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $35,125 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Usage Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 3.4151: Minimize water usage | $31,800 | $136,000 | - | - |
$31,800
-
Tgal
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,325 | $5,710 |
$2,307
57,695
kWh
|
$1,018
-
kW-mo/yr
|
- | - | |
03 | 2.4156: Establish a preventative maintenance program | $2,540 | $4,310 |
$1,400
35,100
kWh
|
$630
-
kW-mo/yr
|
- | $510 | |
04 | 2.7135: Install occupancy sensors | $1,630 | $640 |
$1,630
40,680
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $39,295 | $146,660 |
$5,337
133,475
kWh
|
$1,648
-
kW-mo/yr
|
$31,800
-
Tgal
|
$510 | ||
TOTAL IMPLEMENTED | $35,125 | $141,710 |
$2,307
57,695
kWh
|
$1,018
-
kW-mo/yr
|
$31,800
-
Tgal
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs