| Assessment Year | 2019 |
|---|---|
| Principal Product | Wastewater Treatment |
| NAICS | 221320: Sewage Treatment Facilities |
| SIC | 4953: Refuse Systems |
| Sales Range | less than $500 k |
| # of Employees | 25 |
| Plant Area |
61,600
ft2
|
| Annual Production | 700,800
Tgal
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $99,835 | 1,975,388 |
kWh
|
$0.051 |
| Electricity Demand | $39,635 | 4,840 |
kW-mo/yr
|
$8.19 |
| Electricity Fees | $5,177 | - |
|
- |
| TOTAL YEARLY COSTS | $144,647 | |||
| RECOMMENDED SAVINGS* | $80,920 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $80,920 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 3.1191: Change procedures / equipment / operating conditions | $55,800 | $67,044 |
$42,400
839,368
kWh
|
$13,400
-
kW-mo/yr
|
- | |
| 02 | 2.3212: Optimize plant power factor | $11,700 | $15,300 | - |
$11,700
-
kW-mo/yr
|
- | |
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $9,750 | $22,600 |
$9,750
195,000
kWh
|
- | - | |
| 04 | 2.4157: Establish a predictive maintenance program | $2,760 | $4,570 |
$1,930
38,664
kWh
|
$390
-
kW-mo/yr
|
$440 | |
| 05 | 2.4314: Use synthetic lubricant | $910 | $290 |
$760
15,274
kWh
|
$150
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $80,920 | $109,804 |
$54,840
1,088,306
kWh
|
$25,640
-
kW-mo/yr
|
$440 | ||
| TOTAL IMPLEMENTED | $80,920 | $109,804 |
$54,840
1,088,306
kWh
|
$25,640
-
kW-mo/yr
|
$440 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs