| Assessment Year | 2017 |
|---|---|
| Principal Product | Carbonated beverages |
| NAICS | 312111: Soft Drink Manufacturing |
| SIC | 2086: Bottled and Canned Soft Drinks and Carbonated Waters |
| Sales Range | $50 M to 100M |
| # of Employees | 82 |
| Plant Area |
180,000
ft2
|
| Annual Production | 20,600,000
units
|
| Production Hrs. Annual | 4,772
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $218,858 | 6,153,846 |
kWh
|
$0.036 |
| Electricity Demand | $154,147 | 20,216 |
kW-mo/yr
|
$7.63 |
| Electricity Fees | $12,335 | - |
|
- |
| Natural Gas | $82,431 | 24,693 |
MMBtu
|
$3.34 |
| TOTAL YEARLY COSTS | $467,771 | |||
| RECOMMENDED SAVINGS* | $58,940 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $41,540 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $12,900 | $23,700 | - |
$12,900
-
kW-mo/yr
|
- | - | |
| 02 | 2.3191: Use demand controller or load shedder | $12,700 | - | - | - | $12,700 | - | |
| 03 | 2.4239: Eliminate or reduce compressed air usage | $8,600 | $340 |
$5,580
158,000
kWh
|
$3,020
-
kW-mo/yr
|
- | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,230 | $2,500 |
$3,390
96,100
kWh
|
$1,840
-
kW-mo/yr
|
- | - | |
| 05 | 2.8121: Apply for tax-free status for energy purchases | $10,380 | $3,000 | - | - | $3,460 | $6,920 | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,260 | $3,480 |
$2,120
60,000
kWh
|
$1,140
-
kW-mo/yr
|
- | - | |
| 07 | 3.6192: Use a less expensive method of waste removal | $3,200 | - | - | - | $3,200 | - | |
| 08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,230 | $4,350 |
$1,230
34,900
kWh
|
- | - | - | |
| 09 | 2.4314: Use synthetic lubricant | $860 | - |
$560
16,000
kWh
|
$300
-
kW-mo/yr
|
- | - | |
| 10 | 2.4221: Install compressor air intakes in coolest locations | $580 | $980 |
$350
10,000
kWh
|
$230
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $58,940 | $38,350 |
$13,230
375,000
kWh
|
$19,430
-
kW-mo/yr
|
$19,360 | $6,920 | ||
| TOTAL IMPLEMENTED | $41,540 | $33,890 |
$10,200
289,000
kWh
|
$17,760
-
kW-mo/yr
|
$6,660 | $6,920 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs