| Assessment Year | 2012 |
|---|---|
| Principal Product | Injection molded plastic packaging |
| NAICS | 326130: Laminated Plastics Plate, Sheet (except Packaging), and Shape Manufacturing |
| SIC | 3083: Laminated Plastics Plate, Sheet, and Profile Shapes |
| Sales Range | $50 M to 100M |
| # of Employees | 172 |
| Plant Area |
175,000
ft2
|
| Annual Production | 480,000
thousand feet
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Louisiana |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $717,554 | 10,280,000 |
kWh
|
$0.070 |
| Electricity Demand | $5,407 | 24,956 |
kW-mo/yr
|
$0.22 |
| Electricity Fees | $52,840 | - |
|
- |
| Natural Gas | $116,791 | 17,177 |
MMBtu
|
$6.80 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $60,118 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $45,318 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $21,010 | $38,103 |
$18,472
342,079
kWh
|
$2,538
-
kW-mo/yr
|
- | |
| 02 | 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available | $16,300 | $20,900 |
$14,300
264,600
kWh
|
$2,000
-
kW-mo/yr
|
- | |
| 03 | 2.7261: Install timers and/or thermostats | $14,800 | $2,230 | - | - |
$14,800
-
MMBtu
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,265 | $600 |
$3,840
71,116
kWh
|
$425
-
kW-mo/yr
|
- | |
| 05 | 2.7134: Use photocell controls | $3,000 | $1,000 |
$3,000
54,900
kWh
|
- | - | |
| 06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $694 | $108 |
$608
11,267
kWh
|
$86
-
kW-mo/yr
|
- | |
| 07 | 2.7134: Use photocell controls | $49 | $100 |
$49
900
kWh
|
- | - | |
| TOTAL RECOMMENDED | $60,118 | $63,041 |
$40,269
744,862
kWh
|
$5,049
-
kW-mo/yr
|
$14,800
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $45,318 | $60,811 |
$40,269
744,862
kWh
|
$5,049
-
kW-mo/yr
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs