Assessment Year | 2002 |
---|---|
Principal Product | Rebuilt turbine engine components |
NAICS |
n/a
|
SIC | 3724: Aircraft Engines and Engine Parts |
Sales Range | $5 M to 10M |
# of Employees | 34 |
Plant Area |
38,500
ft2
|
Annual Production | 2,700
pieces
|
Production Hrs. Annual | 2,192
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $50,749 | 747,600 |
kWh
|
$0.068 |
Electricity Fees | $3,989 | - |
|
- |
Natural Gas | $8,202 | 892 |
MMBtu
|
$9.20 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $31,892 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,602 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $18,602 | $2,302 | - | - | - | $4,602 | - | $14,000 | |
02 | 2.6231: Utilize controls to operate equipment only when needed | $5,050 | $750 | - | - | - | - | $5,050 | - | |
03 | 3.5217: Reuse / recycle/ sell paper products | $2,935 | $6,000 | - | - |
$2,935
-
lb
|
- | - | - | |
04 | 4.445: Install equipment to move product | $1,880 | $5,830 | - | - | - | $1,880 | - | - | |
05 | 2.6218: Turn off equipment when not in use | $1,300 | $1,160 |
$1,300
31,200
kWh
|
- | - | - | - | - | |
06 | 2.7124: Make a practice of turning off lights when not needed | $765 | - |
$425
10,350
kWh
|
$340
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $710 | $200 |
$710
17,230
kWh
|
- | - | - | - | - | |
08 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $650 | - | - | - |
$650
-
lb
|
- | - | - | |
TOTAL RECOMMENDED | $31,892 | $16,242 |
$2,435
58,780
kWh
|
$340
-
kW-mo/yr
|
$3,585
-
lb
|
$6,482 | $5,050 | $14,000 | ||
TOTAL IMPLEMENTED | $18,602 | $2,302 | - | - | - | $4,602 | - | $14,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs