| Assessment Year | 1999 |
|---|---|
| Principal Product | Injection molded plastic pails |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 107 |
| Plant Area |
135,000
ft2
|
| Annual Production | 27,100,000
lb
|
| Production Hrs. Annual | 8,568
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $408,495 | 14,352,286 |
kWh
|
$0.028 |
| Electricity Demand | $152,647 | 23,943 |
kW-mo/yr
|
$6.38 |
| Natural Gas | $6,231 | 1,849 |
MMBtu
|
$3.37 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $24,861 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $18,475 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $7,930 | $1,340 |
$6,040
211,899
kWh
|
$1,890
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.3134: Shift from daytime to nighttime operation | $4,270 | - | - |
$4,270
-
kW-mo/yr
|
- | - | - | |
| 03 | 4.445: Install equipment to move product | $3,430 | $100 | - | - | - | $3,430 | - | |
| 04 | 2.7124: Make a practice of turning off lights when not needed | $3,120 | - |
$3,120
109,320
kWh
|
- | - | - | - | |
| 05 | 2.7145: Install skylights | $1,840 | $4,000 |
$1,840
64,771
kWh
|
- | - | - | - | |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $1,350 | $560 |
$1,030
36,342
kWh
|
$320
-
kW-mo/yr
|
- | - | - | |
| 07 | 2.7124: Make a practice of turning off lights when not needed | $1,426 | $384 |
$1,810
63,599
kWh
|
- | - | $(-384.0) | - | |
| 08 | 3.5316: Contract a wood pallet recycling company | $700 | - | - | - |
$700
-
lb
|
- | - | |
| 09 | 2.7124: Make a practice of turning off lights when not needed | $340 | $26 |
$340
12,016
kWh
|
- | - | - | - | |
| 10 | 4.821: Pay bills on time to avoid late fees | $235 | - | - | - | - | - | $235 | |
| 11 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $220 | $90 |
$220
7,913
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $24,861 | $6,500 |
$14,400
505,860
kWh
|
$6,480
-
kW-mo/yr
|
$700
-
lb
|
$3,046 | $235 | ||
| TOTAL IMPLEMENTED | $18,475 | $2,116 |
$7,630
268,170
kWh
|
$6,480
-
kW-mo/yr
|
$700
-
lb
|
$3,430 | $235 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs