| Assessment Year | 1994 |
|---|---|
| Principal Product | Polycrystalline diamond drill bits |
| NAICS |
n/a
|
| SIC | 3533: Oil and Gas Field Machinery and Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 30 |
| Plant Area |
38,000
ft2
|
| Annual Production | 600
pieces
|
| Production Hrs. Annual | 4,460
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $86,483 | 1,206,331 |
kWh
|
$0.072 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $29,445 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,375 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.3137: Use power during off-peak periods | $10,750 | - |
$10,750
-
kWh
|
|
| 02 | 2.3212: Optimize plant power factor | $9,610 | $12,750 |
$9,610
-
kWh
|
|
| 03 | 2.7261: Install timers and/or thermostats | $2,710 | $600 |
$2,710
64,771
kWh
|
|
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $2,240 | - |
$2,240
31,653
kWh
|
|
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,165 | $25 |
$2,165
29,308
kWh
|
|
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,510 | $1,920 |
$1,510
22,274
kWh
|
|
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $460 | $930 |
$460
11,137
kWh
|
|
| TOTAL RECOMMENDED | $29,445 | $16,225 |
$29,445
159,143
kWh
|
||
| TOTAL IMPLEMENTED | $6,375 | $2,875 |
$6,375
94,372
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs