Assessment Year | 1993 |
---|---|
Principal Product | knocked-down corrugated cardboard bo |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 72 |
Plant Area |
300,000
ft2
|
Annual Production | 72,000,000
thousand feet
|
Production Hrs. Annual | 2,044
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $68,191 | 895,662 |
kWh
|
$0.076 |
Natural Gas | $2,939 | 711 |
MMBtu
|
$4.13 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,975 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,395 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2141: Operate distillation columns efficiently | $3,360 | $13,900 | - |
$3,360
-
MMBtu
|
|
02 | 2.6231: Utilize controls to operate equipment only when needed | $2,570 | $1,515 |
$2,570
27,550
kWh
|
- | |
03 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,650 | - |
$1,650
35,170
kWh
|
- | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $755 | $400 |
$755
15,826
kWh
|
- | |
05 | 2.7124: Make a practice of turning off lights when not needed | $640 | $1,115 |
$640
13,482
kWh
|
- | |
TOTAL RECOMMENDED | $8,975 | $16,930 |
$5,615
92,028
kWh
|
$3,360
-
MMBtu
|
||
TOTAL IMPLEMENTED | $1,395 | $1,515 |
$1,395
29,308
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs