Assessment Year 1993
Principal Product BLOWOUT PREVENTERS
NAICS
n/a
SIC 3533: Oil and Gas Field Machinery and Equipment
Sales Range $50
M
to 100
M
# of Employees 400
Plant Area
n/a
Annual Production 3,000
pieces
Production Hrs. Annual 5,976
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $666,273 13,728,898
kWh
Natural Gas $129,335 27,620
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $99,005 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $38,615

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Other Energy Savings
01 2.3212: Optimize plant power factor $40,460 $51,000 $40,460
-
kWh
- -
02 2.3131: Reschedule plant operations or reduce load to avoid peaks $25,000 - $25,000
-
kWh
- -
03 2.7124: Make a practice of turning off lights when not needed $10,100 - - - $10,100
-
MMBtu
04 2.2414: Use waste heat from hot flue gases to preheat $9,490 $20,650 - $9,490
-
MMBtu
-
05 2.2511: Insulate bare equipment $6,070 $3,520 - $6,070
-
MMBtu
-
06 2.7226: Use computer programs to optimize hvac performance $2,660 $300 - $2,660
-
MMBtu
-
07 2.7442: Keep doors and windows shut when not on use $2,360 - $2,360
90,563
kWh
- -
08 2.7134: Use photocell controls $1,155 $570 $1,155
44,549
kWh
- -
09 2.1311: Replace electrically-operated equipment with fossil fuel equipment $1,300 $700 $890
34,291
kWh
$410
-
MMBtu
-
10 2.2531: Re-size charging openings or add movable cover or door $410 $400 - $410
-
MMBtu
-
TOTAL RECOMMENDED $99,005 $77,140 $69,865
169,403
kWh
$19,040
-
MMBtu
$10,100
-
MMBtu
TOTAL IMPLEMENTED $38,615 $570 $28,515
135,112
kWh
- $10,100
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Other Energy Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs