| Assessment Year | 1992 |
|---|---|
| Principal Product | SALT |
| NAICS |
n/a
|
| SIC | 2899: Chemicals and Chemical Preparations, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 85 |
| Plant Area |
n/a
|
| Annual Production | 120,530
ton
|
| Production Hrs. Annual | 7,872
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $289,568 | 4,365,182 |
kWh
|
$0.066 |
| Natural Gas | $611,973 | 389,999 |
MMBtu
|
$1.57 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $23,110 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $21,070 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $18,300 | $35,000 |
$18,300
-
kWh
|
- | |
| 02 | 2.2135: Repair and eliminate steam leaks | $2,440 | $1,240 | - |
$2,440
-
MMBtu
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,420 | $1,360 |
$1,420
29,308
kWh
|
- | |
| 04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $620 | $270 |
$620
10,258
kWh
|
- | |
| 05 | 2.7261: Install timers and/or thermostats | $330 | - |
$330
9,086
kWh
|
- | |
| TOTAL RECOMMENDED | $23,110 | $37,870 |
$20,670
48,652
kWh
|
$2,440
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $21,070 | $36,240 |
$18,630
9,086
kWh
|
$2,440
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs