| Assessment Year | 1992 |
|---|---|
| Principal Product | ship repair |
| NAICS |
n/a
|
| SIC | 3731: Ship Building and Repairing |
| Sales Range | $5 M to 10M |
| # of Employees | 70 |
| Plant Area |
5,900
ft2
|
| Annual Production | 400
pieces
|
| Production Hrs. Annual | 6,060
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $90,034 | 1,145,369 |
kWh
|
$0.079 |
| Other Energy | $9,118 | 149 |
MMBtu
|
$61.19 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,580 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,580 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.6212: Turn off equipment during breaks, reduce operating time | $2,720 | $782 |
$2,720
67,995
kWh
|
|
| 02 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $1,150 | $5,746 |
$1,150
36,635
kWh
|
|
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,010 | $300 |
$1,010
25,205
kWh
|
|
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $700 | $215 |
$700
9,672
kWh
|
|
| TOTAL RECOMMENDED | $5,580 | $7,043 |
$5,580
139,507
kWh
|
||
| TOTAL IMPLEMENTED | $5,580 | $7,043 |
$5,580
139,507
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs