Assessment Year | 1992 |
---|---|
Principal Product | TURBULATORS,HEAT EXCHANGERS |
NAICS |
n/a
|
SIC | 3443: Fabricated Plate Work (Boiler Shops) |
Sales Range | $10 M to 50M |
# of Employees | 102 |
Plant Area |
n/a
|
Annual Production | 4,800
pieces
|
Production Hrs. Annual | 2,453
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $109,198 | 1,348,769 |
kWh
|
$0.081 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,732 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,030 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,535 | $6,730 |
$1,584
10,551
kWh
|
$(-49.0) | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,460 | $530 |
$1,460
28,429
kWh
|
- | |
03 | 2.8123: Pay utility bills on time | $920 | - |
$920
-
kWh
|
- | |
04 | 2.6232: Install set-back timers | $730 | $300 |
$730
14,361
kWh
|
- | |
05 | 2.6232: Install set-back timers | $460 | - |
$460
5,275
kWh
|
- | |
06 | 2.7111: Reduce illumination to minimum necessary levels | $460 | - |
$460
6,448
kWh
|
- | |
07 | 2.6232: Install set-back timers | $167 | - |
$167
3,224
kWh
|
- | |
TOTAL RECOMMENDED | $5,732 | $7,560 |
$5,781
68,288
kWh
|
$(-49.0) | ||
TOTAL IMPLEMENTED | $4,030 | $830 |
$4,030
54,513
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs