Assessment Year 1992
Principal Product FIREPLACES
NAICS
n/a
SIC 3433: Heating Equipment, Except Electric and Warm Air Furnaces
Sales Range $1
M
to 5
M
# of Employees 115
Plant Area
n/a
Annual Production 26,500
pieces
Production Hrs. Annual 4,136
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $53,895 644,490
kWh
Natural Gas $3,431 670
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $3,972 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,170 $1,980 $3,170
89,683
kWh
02 2.8114: Change rate schedules or other changes in utility service $430 $1,000 $430
-
kWh
03 2.6232: Install set-back timers $150 $310 $150
2,345
kWh
04 2.4133: Use most efficient type of electric motors $222 $142 $222
3,517
kWh
TOTAL RECOMMENDED $3,972 $3,432 $3,972
95,545
kWh
TOTAL IMPLEMENTED - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs