Assessment Year | 1990 |
---|---|
Principal Product | GAS TURBINE COGENERATORS |
NAICS |
n/a
|
SIC | 3511: Steam, Gas, and Hydraulic Turbines, and Turbine Generator Set Units |
Sales Range | $100 M to 500M |
# of Employees | 250 |
Plant Area |
n/a
|
Annual Production | 20
pieces
|
Production Hrs. Annual | 2,416
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $217,006 | 3,829,133 |
kWh
|
$0.057 |
Natural Gas | $196,717 | 61,279 |
MMBtu
|
$3.21 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $59,493 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $59,493 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $25,900 | - |
$25,900
307,737
kWh
|
|
02 | 2.3212: Optimize plant power factor | $18,300 | $28,390 |
$18,300
-
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,810 | $9,500 |
$7,810
81,477
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,895 | $990 |
$3,895
43,669
kWh
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,480 | - |
$1,480
16,413
kWh
|
|
06 | 2.6212: Turn off equipment during breaks, reduce operating time | $944 | - |
$944
33,118
kWh
|
|
07 | 2.7111: Reduce illumination to minimum necessary levels | $674 | $160 |
$674
10,844
kWh
|
|
08 | 2.4221: Install compressor air intakes in coolest locations | $490 | $268 |
$490
5,569
kWh
|
|
TOTAL RECOMMENDED | $59,493 | $39,308 |
$59,493
498,827
kWh
|
||
TOTAL IMPLEMENTED | $59,493 | $39,308 |
$59,493
498,827
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs