Assessment Year 1990
Principal Product ACRYLIC & GLASS SKYLIGHT
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $1
M
to 5
M
# of Employees 20
Plant Area
n/a
Annual Production 13,850
pieces
Production Hrs. Annual 1,900
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $18,736 225,088
kWh
Natural Gas $1,145 209
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $846 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $203

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $125 $60 $125
1,465
kWh
- -
02 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available $232 $900 $232
3,810
kWh
- -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $170 $187 $210
3,517
kWh
- $(-40.0)
04 2.1233: Analyze flue gas for proper air/fuel ratio $105 $80 - $105
-
MMBtu
-
05 2.6212: Turn off equipment during breaks, reduce operating time $76 $69 $76
1,172
kWh
- -
06 2.4231: Reduce the pressure of compressed air to the minimum required $67 - $67
1,172
kWh
- -
07 2.2437: Recover waste heat from equipment $38 $194 - $38
-
MMBtu
-
08 2.4221: Install compressor air intakes in coolest locations $33 $33 $33
586
kWh
- -
TOTAL RECOMMENDED $846 $1,523 $743
11,722
kWh
$143
-
MMBtu
$(-40.0)
TOTAL IMPLEMENTED $203 $220 $243
4,103
kWh
- $(-40.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs