Assessment Year 1990
Principal Product POULTRY FEED AND EGGS
NAICS
n/a
SIC 2048: Prepared Feed and Feed Ingredients for Animals and Fowls, Except Dogs and Cats
Sales Range $10
M
to 50
M
# of Employees 130
Plant Area
n/a
Annual Production 1,140,000
ton
Production Hrs. Annual 6,188
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $121,313 2,090,270
kWh
LPG $17,115 2,831
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $40,883 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $40,883

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $30,570 $14,040 $30,570
695,193
kWh
02 2.7447: Install vinyl strip / high speed / air curtain doors $3,960 $2,000 $3,960
116,061
kWh
03 2.2711: Utilize outside air instead of conditioned air for drying $2,910 $4,800 $2,910
77,081
kWh
04 2.3131: Reschedule plant operations or reduce load to avoid peaks $1,720 - $1,720
-
kWh
05 2.7142: Utilize higher efficiency lamps and/or ballasts $691 $698 $691
12,016
kWh
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $422 - $422
12,896
kWh
07 2.3132: Recharge batteries on during off-peak demand periods $330 - $330
-
kWh
08 2.7142: Utilize higher efficiency lamps and/or ballasts $170 $180 $170
3,224
kWh
09 2.4312: Improve lubrication practices $110 - $110
3,224
kWh
TOTAL RECOMMENDED $40,883 $21,718 $40,883
919,695
kWh
TOTAL IMPLEMENTED $40,883 $21,718 $40,883
919,695
kWh
Yearly Savings* Imp'd Cost* Electricity Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs