| Assessment Year | 1999 |
|---|---|
| Principal Product | Fracturing units, blenders, coiled tubing units, data vans, |
| NAICS |
n/a
|
| SIC | 3533: Oil and Gas Field Machinery and Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 120 |
| Plant Area |
122,000
ft2
|
| Annual Production | 73
pieces
|
| Production Hrs. Annual | 3,040
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $113,873 | 2,112,544 |
kWh
|
$0.054 |
| Electricity Demand | $16,960 | 5,591 |
kW-mo/yr
|
$3.03 |
| Electricity Fees | $8,175 | - |
|
- |
| Natural Gas | $20,993 | 3,599 |
MMBtu
|
$5.83 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $45,209 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,329 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $26,500 | $16,000 | - |
$26,500
-
kW-mo/yr
|
- | - | - | - | |
| 02 | 2.8121: Apply for tax-free status for energy purchases | $10,800 | $7,200 | - | - | $10,800 | - | - | - | |
| 03 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $2,430 | $500 | - | - | - |
$2,430
-
lb
|
- | - | |
| 04 | 2.7131: Add area lighting switches | $1,920 | $310 |
$650
23,447
kWh
|
$1,270
-
kW-mo/yr
|
- | - | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,650 | $650 |
$125
4,396
kWh
|
$85
-
kW-mo/yr
|
- | - | $1,440 | - | |
| 06 | 2.7131: Add area lighting switches | $1,240 | $150 |
$390
14,654
kWh
|
$850
-
kW-mo/yr
|
- | - | - | - | |
| 07 | 2.8123: Pay utility bills on time | $274 | - | - | - | - | - | - | $274 | |
| 08 | 2.7124: Make a practice of turning off lights when not needed | $255 | - |
$60
2,052
kWh
|
$195
-
kW-mo/yr
|
- | - | - | - | |
| 09 | 2.7124: Make a practice of turning off lights when not needed | $140 | - |
$40
1,465
kWh
|
$100
-
kW-mo/yr
|
- | - | - | - | |
| TOTAL RECOMMENDED | $45,209 | $24,810 |
$1,265
46,014
kWh
|
$29,000
-
kW-mo/yr
|
$10,800 |
$2,430
-
lb
|
$1,440 | $274 | ||
| TOTAL IMPLEMENTED | $11,329 | $7,200 |
$60
2,052
kWh
|
$195
-
kW-mo/yr
|
$10,800 | - | - | $274 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs