Assessment Year | 1990 |
---|---|
Principal Product | HYDRAULIC EQUIPMENT |
NAICS |
n/a
|
SIC | 3537: Industrial Trucks, Tractors, Trailers, and Stackers |
Sales Range | $10 M to 50M |
# of Employees | 125 |
Plant Area |
n/a
|
Annual Production | 1,500
pieces
|
Production Hrs. Annual | 4,692
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $119,791 | 1,997,655 |
kWh
|
$0.060 |
Natural Gas | $48,561 | 10,135 |
MMBtu
|
$4.79 |
Fuel Oil #1 | $4,100 | 500 |
MMBtu
|
$8.20 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $18,200 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $14,470 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #1 Savings |
---|---|---|---|---|---|---|---|
01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $6,080 | $14,110 |
$6,080
131,008
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,360 | $2,000 |
$3,360
72,392
kWh
|
- | - | |
03 | 2.2414: Use waste heat from hot flue gases to preheat | $3,730 | $12,000 |
$(-3,790.0)
(-82,063)
kWh
|
$7,520
-
MMBtu
|
- | |
04 | 2.7291: Reschedule and rearrange multiple-source heating systems | $2,824 | $2,150 | - |
$(-2,391.0)
-
MMBtu
|
$5,215
-
MMBtu
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,380 | - |
$1,380
29,601
kWh
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $206 | $208 |
$206
2,931
kWh
|
- | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $620 | $600 |
$620
13,189
kWh
|
- | - | |
TOTAL RECOMMENDED | $18,200 | $31,068 |
$7,856
167,058
kWh
|
$5,129
-
MMBtu
|
$5,215
-
MMBtu
|
||
TOTAL IMPLEMENTED | $14,470 | $19,068 |
$11,646
249,121
kWh
|
$(-2,391.0)
-
MMBtu
|
$5,215
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #1 Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs