| Assessment Year | 1989 |
|---|---|
| Principal Product | OILFIELD VALVES & EQUIPMENT |
| NAICS |
n/a
|
| SIC | 3533: Oil and Gas Field Machinery and Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 75 |
| Plant Area |
n/a
|
| Annual Production | 500
pieces
|
| Production Hrs. Annual | 2,912
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $40,591 | 625,147 |
kWh
|
$0.065 |
| Natural Gas | $7,335 | 1,626 |
MMBtu
|
$4.51 |
| Other Energy | $6,240 | 811 |
MMBtu
|
$7.69 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,867 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,987 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Energy Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $2,350 | $3,160 |
$2,350
56,272
kWh
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,090 | $7,752 |
$2,090
35,170
kWh
|
- | - | |
| 03 | 2.2443: Re-use or recycle hot or cold process exhaust air | $1,440 | $2,000 | - |
$1,440
-
MMBtu
|
- | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $828 | $500 |
$828
19,930
kWh
|
- | - | |
| 05 | 2.8227: Adjust / maintain fork lift trucks for most efficient operation | $624 | $420 | - | - |
$624
-
MMBtu
|
|
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $119 | $95 |
$119
2,052
kWh
|
- | - | |
| 07 | 2.7111: Reduce illumination to minimum necessary levels | $300 | $105 |
$300
5,569
kWh
|
- | - | |
| 08 | 2.6232: Install set-back timers | $116 | - |
$116
2,931
kWh
|
- | - | |
| TOTAL RECOMMENDED | $7,867 | $14,032 |
$5,803
121,924
kWh
|
$1,440
-
MMBtu
|
$624
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $1,987 | $1,120 |
$1,363
30,482
kWh
|
- |
$624
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Other Energy Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs