Assessment Year | 1989 |
---|---|
Principal Product | HEAT TREATED METAL PARTS |
NAICS |
n/a
|
SIC | 3398: Metal Heat Treating |
Sales Range | $1 M to 5M |
# of Employees | 22 |
Plant Area |
n/a
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,008
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $24,806 | 343,787 |
kWh
|
$0.072 |
Natural Gas | $9,169 | 2,134 |
MMBtu
|
$4.30 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,880 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,688 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $1,987 | $6,125 |
$(-391.0)
(-4,103)
kWh
|
$2,378
-
MMBtu
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,275 | $5,730 |
$1,275
16,999
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $48 | $11 |
$48
586
kWh
|
- | |
04 | 2.6232: Install set-back timers | $250 | $50 |
$250
5,275
kWh
|
- | |
05 | 2.6232: Install set-back timers | $205 | - |
$205
4,396
kWh
|
- | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $115 | $300 |
$115
2,638
kWh
|
- | |
TOTAL RECOMMENDED | $3,880 | $12,216 |
$1,502
25,791
kWh
|
$2,378
-
MMBtu
|
||
TOTAL IMPLEMENTED | $1,688 | $6,091 |
$1,688
25,498
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs