Assessment Year | 2025 |
---|---|
Principal Product | Casino recreation |
NAICS | 713210: Casinos (except Casino Hotels) |
SIC | 7999: Amusement and Recreation Services, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 75 |
Plant Area |
73,000
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 6,570
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $258,915 | 3,983,308 |
kWh
|
$0.065 | |
Natural Gas | $9,790 | 1,868 |
MMBtu
|
$5.24 | |
Waste Disposal Costs | |||||
Water Usage | $15,531 | 3,106 |
Tgal
|
$5.00 | |
TOTAL YEARLY COSTS | $284,236 | ||||
RECOMMENDED SAVINGS* | $33,116 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,062 | $4,276 |
$3,062
47,110
kWh
|
|
02 | 2.9114: Use solar heat to make electricty | $11,898 | $117,000 |
$11,898
183,045
kWh
|
|
03 | 2.7232: Replace existing hvac unit with high efficiency model | $2,296 | $6,930 |
$2,296
35,319
kWh
|
|
04 | 2.7211: Clean and maintain refrigerant condensers and towers | $15,493 | $10,910 |
$15,493
238,350
kWh
|
|
05 | 2.6211: Conserve energy by efficient use of vending machines | $367 | $380 |
$367
5,641
kWh
|
|
TOTAL RECOMMENDED | $33,116 | $139,496 |
$33,116
509,465
kWh
|
||
TOTAL IMPLEMENTED | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs