Assessment Year | 1988 |
---|---|
Principal Product | CYLINDERS, PUMPS, MOTORS |
NAICS |
n/a
|
SIC | 3593: Fluid Power Cylinders and Actuators |
Sales Range | $5 M to 10M |
# of Employees | 50 |
Plant Area |
n/a
|
Annual Production | 5,000
pieces
|
Production Hrs. Annual | 2,660
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $25,630 | 352,579 |
kWh
|
$0.073 |
Natural Gas | $11,693 | 2,417 |
MMBtu
|
$4.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $3,545 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,270 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $1,838 | $3,000 |
$1,838
-
kWh
|
- | - | |
02 | 2.6218: Turn off equipment when not in use | $645 | $40 |
$45
1,465
kWh
|
$600
-
MMBtu
|
- | |
03 | 3.4154: Eliminate leaks in water lines and valves | $400 | $40 | - | - | $400 | |
04 | 2.2437: Recover waste heat from equipment | $275 | $550 | - |
$275
-
MMBtu
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $48 | $32 |
$48
879
kWh
|
- | - | |
06 | 2.7261: Install timers and/or thermostats | $194 | $225 |
$60
2,052
kWh
|
$134
-
MMBtu
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $145 | $336 |
$105
3,224
kWh
|
- | $40 | |
TOTAL RECOMMENDED | $3,545 | $4,223 |
$2,096
7,620
kWh
|
$1,009
-
MMBtu
|
$440 | ||
TOTAL IMPLEMENTED | $3,270 | $3,673 |
$2,096
7,620
kWh
|
$734
-
MMBtu
|
$440 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs