Assessment Year | 2002 |
---|---|
Principal Product | Sheet Meet Ducting |
NAICS |
n/a
|
SIC | 3444: Sheet Metal Work |
Sales Range | $10 M to 50M |
# of Employees | 30 |
Plant Area |
100,000
ft2
|
Annual Production | 4,500,000
lb
|
Production Hrs. Annual | 2,008
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $46,494 | 850,078 |
kWh
|
$0.055 |
Electricity Demand | $22,041 | 3,008 |
kW-mo/yr
|
$7.33 |
Electricity Fees | $7,827 | - |
|
- |
Natural Gas | $11,180 | 2,066 |
MMBtu
|
$5.41 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,016 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,775 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $12,980 | - | - | - | $12,980 | |
02 | 2.8121: Apply for tax-free status for energy purchases | $5,735 | - | - | - | $5,735 | |
03 | 2.7221: Lower temperature during the winter season and vice-versa | $1,390 | - |
$1,390
33,968
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $670 | - |
$238
5,815
kWh
|
$432
-
kW-mo/yr
|
- | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $140 | $75 |
$140
3,370
kWh
|
- | - | |
06 | 2.7135: Install occupancy sensors | $101 | $163 |
$101
2,465
kWh
|
- | - | |
TOTAL RECOMMENDED | $21,016 | $238 |
$1,869
45,618
kWh
|
$432
-
kW-mo/yr
|
$18,715 | ||
TOTAL IMPLEMENTED | $20,775 | - |
$1,628
39,783
kWh
|
$432
-
kW-mo/yr
|
$18,715 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs