| Assessment Year | 1988 |
|---|---|
| Principal Product | PRE-HUNG DOOR UNITS |
| NAICS |
n/a
|
| SIC | 2431: Millwork |
| Sales Range | $10 M to 50M |
| # of Employees | 75 |
| Plant Area |
n/a
|
| Annual Production | 46,800
pieces
|
| Production Hrs. Annual | 2,032
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $91,650 | 1,143,025 |
kWh
|
$0.080 |
| LPG | $6,313 | 1,053 |
MMBtu
|
$6.00 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,728 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $1,085 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,437 | $2,782 |
$2,190
26,964
kWh
|
- | $247 | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $690 | - |
$690
16,999
kWh
|
- | - | |
| 03 | 2.6214: Shut off pilots in standby equipment | $476 | - | - |
$476
-
MMBtu
|
- | |
| 04 | 2.2437: Recover waste heat from equipment | $425 | $1,520 | - |
$425
-
MMBtu
|
- | |
| 05 | 2.4312: Improve lubrication practices | $395 | - |
$395
9,672
kWh
|
- | - | |
| 06 | 2.7261: Install timers and/or thermostats | $305 | $225 |
$305
7,620
kWh
|
- | - | |
| TOTAL RECOMMENDED | $4,728 | $4,527 |
$3,580
61,255
kWh
|
$901
-
MMBtu
|
$247 | ||
| TOTAL IMPLEMENTED | $1,085 | - |
$1,085
26,671
kWh
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs