ITAC Assessment: AM0014
ITAC logo
ITAC Assessment: AM0014
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1987
Principal Product PREFABRICATED METAL BUILDINGS
NAICS
n/a
SIC 3448: Prefabricated Metal Buildings and Components
Sales Range $10
M
to 50
M
# of Employees 160
Plant Area
n/a
Annual Production 120
pieces
Production Hrs. Annual 2,600
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $36,539 483,880
kWh
LPG $7,358 943
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $3,427 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $2,605

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings LPG Savings
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $945 $300 $945
27,843
kWh
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $279 $94 $279
4,396
kWh
-
04 2.7111: Reduce illumination to minimum necessary levels $555 - $555
8,499
kWh
-
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $460 $300 $460
13,482
kWh
-
06 2.7261: Install timers and/or thermostats $362 $500 $362
13,189
kWh
-
07 2.2437: Recover waste heat from equipment $460 $200 - $460
-
MMBtu
08 2.7133: Use separate switches on perimeter lighting which may be turned off when natural light is available $283 $50 $283
8,206
kWh
-
09 2.7142: Utilize higher efficiency lamps and/or ballasts $83 $67 $83
1,172
kWh
-
TOTAL RECOMMENDED $3,427 $1,511 $2,967
76,787
kWh
$460
-
MMBtu
TOTAL IMPLEMENTED $2,605 $1,150 $2,605
71,219
kWh
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings LPG Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs