The ITAC Statistics page displays the average assessment results for the selected criteria.
NAICS | 312112 | Bottled water manufacturing |
20
Matching Assessments
Initial Plant Size Averages | Costs | Usage | Unit Cost | |
---|---|---|---|---|
All Energy | $1,531k | 212k |
MMBtu
|
$9.07 |
- Electrical | $1,075k | 18,705k |
kWh
|
$0.064 |
- Natural Gas | $95k | 20k |
MMBtu
|
$6.67 |
149
Recommendations
7.5
Recommendations Per Assessment
Average Recommended Rec'd Savings By Type* | Cost Savings | Usage Reduction | % Usage Reduction |
|
---|---|---|---|---|
All Energy | $136k | 16k |
MMBtu
|
7.7% |
- Electrical | $98k | 1,587k |
kWh
|
8.5% |
- Natural Gas | $13k | - |
MMBtu
|
- |
Waste | $2.9k | |||
Productivity/Other | $247k | |||
TOTAL | $386k | |||
*May be negative reflecting an increased cost component required to save energy and costs overall |
16
with Implementation Data
Initial Plant Size Averages | Costs | Usage | Unit Cost | |
---|---|---|---|---|
All Energy | $1,165k | 160k |
MMBtu
|
$9.03 |
- Electrical | $852k | 13,865k |
kWh
|
$0.064 |
- Natural Gas | $92k | 18k |
MMBtu
|
$6.09 |
57
Implemented Recommendations
3.6
Implemented Per Assessment
Average Recommended Rec'd Savings By Type* | Cost Savings | Usage Reduction | % Usage Reduction |
|
---|---|---|---|---|
All Energy | $63k | 6.8k |
MMBtu
|
4.2% |
- Electrical | $48k | 660k |
kWh
|
4.8% |
- Natural Gas | $4.1k | - |
MMBtu
|
- |
Waste | $1.8k | |||
Productivity/Other | $4.4k | |||
TOTAL | $69k | |||
*May be negative reflecting an increased cost component required to save energy and costs overall |