| IA0508 #10 Y:2013 | 10 | 2013 | Eliminate leaks in inert gas and compressed air lines/ valves | $8,022 | $210 | |
| IA0508 #09 Y:2013 | 09 | 2013 | Install / repair insulation on steam lines | $3,758 | $976 | |
| IA0508 #08 Y:2013 | 08 | 2013 | Analyze flue gas for proper air/fuel ratio | $3,512 | $1,000 | |
| IA0508 #07 Y:2013 | 07 | 2013 | Utilize higher efficiency lamps and/or ballasts | $598 | $394 | |
| IA0508 #06 Y:2013 | 06 | 2013 | Install occupancy sensors | $6,734 | $5,775 | |
| IA0508 #05 Y:2013 | 05 | 2013 | Utilize controls to operate equipment only when needed | $689 | $1,590 | |
| IA0508 #04 Y:2013 | 04 | 2013 | Optimize plant power factor | $6,113 | $6,000 | |
| IA0508 #03 Y:2013 | 03 | 2013 | Direct warmest air to combustion intake | $2,845 | $1,000 | |
| IA0508 #02 Y:2013 | 02 | 2013 | Repair or replace steam traps | $14,349 | $3,750 | |
| IA0508 #01 Y:2013 | 01 | 2013 | Recycle air for heating, ventilation and air conditioning | $218,077 | $1,045,200 |