| Assessment Year | 2026 |
|---|---|
| Principal Product | Opal & Crystal Glass Products |
| NAICS | 327212: Other Pressed and Blown Glass and Glassware Manufacturing |
| SIC | 3229: Pressed and Blown Glass and Glassware, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 75 |
| Plant Area |
40,000
ft2
|
| Annual Production | 900
ton
|
| Production Hrs. Annual | 2,210
hrs
|
| Location (State) | West Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $61,816 | 454,183 |
kWh
|
$0.14 |
| Natural Gas | $127,264 | 41,765 |
MMBtu
|
$3.05 |
| TOTAL YEARLY COSTS | $189,080 | |||
| RECOMMENDED SAVINGS* | $12,412 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $5,151 | $3,159 | - |
$5,151
-
MMBtu
|
|
| 02 | 2.2511: Insulate bare equipment | $2,406 | $972 | - |
$2,406
-
MMBtu
|
|
| 03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,222 | $2,159 | - |
$2,222
-
MMBtu
|
|
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,104 | $1,600 |
$1,104
8,118
kWh
|
- | |
| 05 | 2.2414: Use waste heat from hot flue gases to preheat | $1,009 | $3,255 | - |
$1,009
-
MMBtu
|
|
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $520 | $1,456 |
$520
3,823
kWh
|
- | |
| TOTAL RECOMMENDED | $12,412 | $12,601 |
$1,624
11,941
kWh
|
$10,788
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs