Assessment Year 2024
Principal Product hydraulic piston pumps
NAICS 333996: Fluid Power Pump and Motor Manufacturing
SIC 3594: Fluid Power Pumps and Motors
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 90,200
ft2
Annual Production 40,000
units
Production Hrs. Annual 6,240
hrs
Location (State) South Carolina

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $293,450 4,853,616
kWh
Electricity Demand $180,600 9,619
kW-mo/yr
Electricity Fees $22,155 -
Natural Gas $15,843 1,331
MMBtu
TOTAL YEARLY COSTS $512,048
RECOMMENDED SAVINGS* $35,306 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $1,874 $6,020 $1,874
30,787
kWh
-
02 2.7229: Air condition only space necessary $8,109 - $5,676
94,608
kWh
$2,433
-
kW-mo/yr
03 2.7135: Install occupancy sensors $4,448 $6,882 $4,448
74,132
kWh
-
04 2.4231: Reduce the pressure of compressed air to the minimum required $5,256 - $3,679
61,320
kWh
$1,577
-
kW-mo/yr
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $180 $308 $180
2,993
kWh
-
06 2.7224: Reduce space conditioning during non-working hours $12,484 - $12,484
208,073
kWh
-
07 2.7316: Centralize control of exhaust fans to ensure their shutdown, or establish program to ensure manual shutdown $563 - $394
6,570
kWh
$169
-
kW-mo/yr
08 2.4239: Eliminate or reduce compressed air usage $2,392 - $2,392
39,874
kWh
-
TOTAL RECOMMENDED $35,306 $13,210 $31,127
518,357
kWh
$4,179
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs