ITAC Assessment: WV0675
ITAC logo
ITAC Assessment: WV0675
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Commercial Screen Printing
NAICS 323113: Commercial Screen Printing
SIC 2759: Commercial Printing, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 189
Plant Area 225,000
ft2
Annual Production 500,000
units
Production Hrs. Annual 6,240
hrs
Location (State) West Virginia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $229,051 3,435,403
kWh
Electricity Demand $218,881 14,185
kW-mo/yr
Electricity Fees $5,197 -
LPG $33,968 1,995
MMBtu
TOTAL YEARLY COSTS $487,097
RECOMMENDED SAVINGS* $216,725 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings LPG Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $163,920 $663,966 $117,445
1,760,790
kWh
$46,475
-
kW-mo/yr
- -
02 2.7232: Replace existing hvac unit with high efficiency model $24,663 $80,657 $18,445
276,544
kWh
$6,218
-
kW-mo/yr
- -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $12,514 $29,651 $8,656
129,768
kWh
$3,858
-
kW-mo/yr
- -
04 2.7135: Install occupancy sensors $6,065 $25,395 $4,013
60,164
kWh
$2,052
-
kW-mo/yr
- -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,602 $252 $1,801
26,999
kWh
$801
-
kW-mo/yr
- -
06 2.3212: Optimize plant power factor $1,934 $4,653 - - $1,934 -
07 2.7241: Install outside air damper / economizer on hvac unit $1,456 $6,768 $1,194
17,904
kWh
$262
-
kW-mo/yr
- -
08 2.4221: Install compressor air intakes in coolest locations $1,305 $1,422 $474
7,106
kWh
$508
-
kW-mo/yr
- $323
-
MMBtu
09 2.4224: Upgrade controls on compressors $1,087 $3,439 $871
13,064
kWh
$216
-
kW-mo/yr
- -
10 2.4239: Eliminate or reduce compressed air usage $664 $1,243 $463
6,940
kWh
$201
-
kW-mo/yr
- -
11 2.4231: Reduce the pressure of compressed air to the minimum required $515 $26 $361
5,408
kWh
$154
-
kW-mo/yr
- -
TOTAL RECOMMENDED $216,725 $817,472 $153,723
2,304,687
kWh
$60,745
-
kW-mo/yr
$1,934 $323
-
MMBtu
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings LPG Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs