| Assessment Year | 2024 |
|---|---|
| Principal Product | Food Grade Plastic Containers |
| NAICS | 326111: Plastics Bag and Pouch Manufacturing |
| SIC | 2673: Plastics, Foil, and Coated Paper Bags |
| Sales Range | $50 M to 100M |
| # of Employees | 200 |
| Plant Area |
172,000
ft2
|
| Annual Production | 50,000,000
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | West Virginia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,121,476 | 24,134,014 |
kWh
|
$0.046 |
| Electricity Demand | $802,649 | 43,064 |
kW-mo/yr
|
$18.64 |
| Electricity Fees | $5,274 | - |
|
- |
| Natural Gas | $115,312 | 46,295 |
MMBtu
|
$2.49 |
| TOTAL YEARLY COSTS | $2,044,711 | |||
| RECOMMENDED SAVINGS* | $118,666 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $95,758 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4157: Establish a predictive maintenance program | $46,042 | $4,000 |
$34,139
734,166
kWh
|
$19,553
-
kW-mo/yr
|
- | $(-7,650.0) | - | |
| 02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $20,234 | $90,000 |
$12,853
276,411
kWh
|
$7,381
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.2511: Insulate bare equipment | $12,543 | $934 |
$7,976
171,537
kWh
|
$4,567
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4157: Establish a predictive maintenance program | $12,305 | $1,500 |
$12,765
274,525
kWh
|
$7,307
-
kW-mo/yr
|
- | $(-7,767.0) | - | |
| 05 | 2.4151: Develop a repair/replace policy | $10,700 | $3,650 |
$7,181
154,420
kWh
|
$4,119
-
kW-mo/yr
|
- | - | $(-600.0) | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,787 | $900 |
$4,954
106,529
kWh
|
$2,833
-
kW-mo/yr
|
- | - | - | |
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $5,056 | $7,004 |
$3,211
69,044
kWh
|
$1,845
-
kW-mo/yr
|
- | - | - | |
| 08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,674 | $10,167 |
$1,108
23,834
kWh
|
$1,566
-
kW-mo/yr
|
- | - | - | |
| 09 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,325 | $952 | - | - |
$1,325
-
MMBtu
|
- | - | |
| TOTAL RECOMMENDED | $118,666 | $119,107 |
$84,187
1,810,466
kWh
|
$49,171
-
kW-mo/yr
|
$1,325
-
MMBtu
|
$(-15,417.0) | $(-600.0) | ||
| TOTAL IMPLEMENTED | $95,758 | $18,940 |
$70,226
1,510,221
kWh
|
$40,224
-
kW-mo/yr
|
$1,325
-
MMBtu
|
$(-15,417.0) | $(-600.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs