Assessment Year | 2012 |
---|---|
Principal Product | plastic bottles and technology assistance |
NAICS | 325998: All Other Miscellaneous Chemical Product and Preparation Manufacturing |
SIC | 2819: Industrial Inorganic Chemicals, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 68 |
Plant Area |
43,000
ft2
|
Annual Production | 100
ton
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $105,697 | 1,205,040 |
kWh
|
$0.088 |
Electricity Demand | $31,047 | 4,901 |
kW-mo/yr
|
$6.33 |
Natural Gas | $26,299 | 3,688 |
MMBtu
|
$7.13 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $24,471 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,924 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,725 | $9,258 |
$4,615
52,611
kWh
|
$1,110
-
kW-mo/yr
|
- | |
02 | 2.7492: Use proper thickness of insulation on building envelope | $5,053 | $51,600 |
$360
4,102
kWh
|
$51
-
kW-mo/yr
|
$4,642
-
MMBtu
|
|
03 | 2.7232: Replace existing hvac unit with high efficiency model | $3,859 | $16,925 |
$3,510
40,022
kWh
|
$349
-
kW-mo/yr
|
- | |
04 | 2.2492: Use "heat wheel" or other heat exchanger to cross-exchange building exhaust air with make-up air | $3,243 | $14,500 |
$231
2,637
kWh
|
$25
-
kW-mo/yr
|
$2,987
-
MMBtu
|
|
05 | 2.7135: Install occupancy sensors | $1,979 | $1,826 |
$1,979
22,558
kWh
|
- | - | |
06 | 2.7231: Use radiant heater for spot heating | $1,968 | $10,438 | - | - |
$1,968
-
MMBtu
|
|
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,424 | $5,689 |
$1,189
13,557
kWh
|
$235
-
kW-mo/yr
|
- | |
08 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,103 | $1,000 |
$956
10,904
kWh
|
$147
-
kW-mo/yr
|
- | |
09 | 2.4231: Reduce the pressure of compressed air to the minimum required | $117 | $7 |
$104
1,186
kWh
|
$13
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $24,471 | $111,243 |
$12,944
147,577
kWh
|
$1,930
-
kW-mo/yr
|
$9,597
-
MMBtu
|
||
TOTAL IMPLEMENTED | $8,924 | $12,091 |
$7,654
87,259
kWh
|
$1,270
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs