| Assessment Year | 2005 |
|---|---|
| Principal Product | High Voltage Circuit Breaker |
| NAICS | 335932: Noncurrent-Carrying Wiring Device Manufacturing |
| SIC | 3613: Switchgear and Switchboard Apparatus |
| Sales Range | $100 M to 500M |
| # of Employees | 246 |
| Plant Area |
130,000
ft2
|
| Annual Production | 37,440
pieces
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $108,353 | 2,815,200 |
kWh
|
$0.038 |
| Electricity Demand | $30,941 | 6,030 |
kW-mo/yr
|
$5.13 |
| Electricity Fees | $8,366 | - |
|
- |
| Natural Gas | $22,122 | 139 |
MMBtu
|
$159.15 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $22,240 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $20,402 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $14,602 | - | - | - | - | $14,602 | |
| 02 | 2.7131: Add area lighting switches | $3,316 | $1,325 |
$3,316
86,112
kWh
|
- | - | - | |
| 03 | 2.7144: Install spectral reflectors / delamp | $1,364 | $3,679 |
$948
24,525
kWh
|
$416
-
kW-mo/yr
|
- | - | |
| 04 | 2.7224: Reduce space conditioning during non-working hours | $1,049 | $35 |
$1,049
27,249
kWh
|
- | - | - | |
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $789 | $6 |
$666
17,403
kWh
|
$123
-
kW-mo/yr
|
- | - | |
| 06 | 2.7135: Install occupancy sensors | $508 | $105 |
$508
13,209
kWh
|
- | - | - | |
| 07 | 2.6218: Turn off equipment when not in use | $474 | $140 |
$474
12,306
kWh
|
- | - | - | |
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $138 | $95 |
$147
3,921
kWh
|
$26
-
kW-mo/yr
|
$(-35.0) | - | |
| TOTAL RECOMMENDED | $22,240 | $5,385 |
$7,108
184,725
kWh
|
$565
-
kW-mo/yr
|
$(-35.0) | $14,602 | ||
| TOTAL IMPLEMENTED | $20,402 | $1,566 |
$5,686
147,894
kWh
|
$149
-
kW-mo/yr
|
$(-35.0) | $14,602 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs