Assessment Year | 2003 |
---|---|
Principal Product | Plastic Extrusions |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 85 |
Plant Area |
90,000
ft2
|
Annual Production | 8,000,000
lb
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $123,279 | 1,828,440 |
kWh
|
$0.067 |
Natural Gas | $9,625 | 894 |
MMBtu
|
$10.77 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $42,192 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,707 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $217 | $450 |
$217
3,223
kWh
|
- | |
02 | 2.2515: Use optimum thickness insulation | $2,207 | $375 | - |
$2,207
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,449 | $10,381 |
$6,449
95,620
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $144 | $136 |
$144
2,132
kWh
|
- | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,897 | $50 |
$1,897
28,128
kWh
|
- | |
06 | 2.4221: Install compressor air intakes in coolest locations | $494 | $185 |
$494
7,325
kWh
|
- | |
07 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $3,930 | $250 |
$3,930
62,702
kWh
|
- | |
08 | 2.2511: Insulate bare equipment | $12,370 | $1,015 |
$12,370
183,418
kWh
|
- | |
09 | 2.4239: Eliminate or reduce compressed air usage | $5,414 | $420 |
$5,414
80,350
kWh
|
- | |
10 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,727 | $250 |
$2,727
40,436
kWh
|
- | |
11 | 2.7111: Reduce illumination to minimum necessary levels | $6,126 | $800 |
$6,126
90,830
kWh
|
- | |
12 | 2.2625: Chill water to the highest temperature possible | $217 | $50 |
$217
3,223
kWh
|
- | |
TOTAL RECOMMENDED | $42,192 | $14,362 |
$39,985
597,387
kWh
|
$2,207
-
MMBtu
|
||
TOTAL IMPLEMENTED | $21,707 | $12,367 |
$21,707
326,294
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs