Assessment Year | 2000 |
---|---|
Principal Product | Processed Vegetables |
NAICS |
n/a
|
SIC | 2099: Food Preparations, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 410 |
Plant Area |
80,000
ft2
|
Annual Production | 89,000,000
lb
|
Production Hrs. Annual | 6,916
hrs
|
Location (State) | West Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $345,199 | 6,756,155 |
kWh
|
$0.051 |
Natural Gas | $8,627 | 1,092 |
MMBtu
|
$7.90 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $253,348 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $29,425 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $5,539 | $60 |
$5,539
108,441
kWh
|
- | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,677 | $175 |
$1,677
32,825
kWh
|
- | - | |
03 | 2.2628: Utilize a less expensive cooling method | $5,450 | $1,870 |
$5,450
106,682
kWh
|
- | - | |
04 | 2.2621: Modify refrigeration system to operate at a lower pressure | $1,200 | $70 |
$1,200
23,447
kWh
|
- | - | |
05 | 2.7144: Install spectral reflectors / delamp | $1,009 | $1,458 |
$1,009
19,637
kWh
|
- | - | |
06 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $35,688 | $6,000 |
$35,688
698,710
kWh
|
- | - | |
07 | 2.2624: Use cold waste water to cool chiller feed water | $7,785 | $12,000 |
$7,785
152,403
kWh
|
- | - | |
08 | 3.3122: Use filtration, centrifuging to remove contaminants | $56,000 | $69,950 | - |
$56,000
-
lb
|
- | |
09 | 3.6126: Direct waste gasses to boiler combustion air | $119,000 | $250,000 | - |
$119,000
-
lb
|
- | |
10 | 4.652: Replace existing equipment with more suitable substitutes | $20,000 | $7,000 | - | - | $20,000 | |
TOTAL RECOMMENDED | $253,348 | $348,583 |
$58,348
1,142,145
kWh
|
$175,000
-
lb
|
$20,000 | ||
TOTAL IMPLEMENTED | $29,425 | $8,763 |
$9,425
184,350
kWh
|
- | $20,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs