Assessment Year 1998
Principal Product Carbon and carbon products
NAICS
n/a
SIC 3370:
Sales Range $1
M
to 5
M
# of Employees 21
Plant Area 87,120
ft2
Annual Production 6,000
ton
Production Hrs. Annual 4,160
hrs
Location (State) West Virginia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $105,042 2,041,911
kWh
Electricity Demand $24,878 4,862
kW-mo/yr
Electricity Fees $2,356 -
Fuel Oil #2 $94,798 22,278
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $71,662 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $25,874

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Gas Savings Solid Waste (non-haz) Savings Ancillary Material Cost Savings
01 2.7122: Disconnect ballasts $2,140 $1,080 $2,140
54,513
kWh
- - - - -
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $300 $105 $300
7,620
kWh
- - - - -
03 2.4314: Use synthetic lubricant $276 $212 $276
7,034
kWh
- - - - -
04 2.6212: Turn off equipment during breaks, reduce operating time $230 - $230
5,862
kWh
- - - - -
05 2.1331: Burn a less expensive grade of fuel $4,340 $7,200 - - - $4,340
-
MMBtu
- -
06 2.4133: Use most efficient type of electric motors $152 $1,400 $60
5,275
kWh
$92
-
kW-mo/yr
- - - -
07 2.6218: Turn off equipment when not in use $4,570 - $4,570
116,354
kWh
- - - - -
08 2.2437: Recover waste heat from equipment $418 $156 - - $418
-
MMBtu
- - -
09 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $261 $40 $261
6,741
kWh
- - - - -
10 3.5248: Separate and recycle scrap metal to foundry or for sale $16,800 $400 - - - - $16,800
-
lb
-
11 3.5316: Contract a wood pallet recycling company $1,375 $200 - - - - $1,375
-
lb
-
12 4.211: Consider use / purchase of bulk materials where possible $40,800 $50,000 - - - - - $40,800
TOTAL RECOMMENDED $71,662 $60,793 $7,837
203,399
kWh
$92
-
kW-mo/yr
$418
-
MMBtu
$4,340
-
MMBtu
$18,175
-
lb
$40,800
TOTAL IMPLEMENTED $25,874 $3,437 $7,607
197,537
kWh
$92
-
kW-mo/yr
- - $18,175
-
lb
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Gas Savings Solid Waste (non-haz) Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs