Assessment Year | 1998 |
---|---|
Principal Product | Stamped lead Plates |
NAICS |
n/a
|
SIC | 3469: Metal Stampings, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
50,000
ft2
|
Annual Production | 600,000
lb
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $237,321 | 4,883,060 |
kWh
|
$0.049 |
Natural Gas | $12,822 | 1,326 |
MMBtu
|
$9.67 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $75,195 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $32,254 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Other Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $3,346 | $1,000 | - |
$3,346
-
MMBtu
|
- | - | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $6,131 | $10,800 |
$6,131
126,319
kWh
|
- | - | - | - | - | |
03 | 2.1331: Burn a less expensive grade of fuel | $2,650 | $2,400 | - | - |
$2,650
-
MMBtu
|
- | - | - | |
04 | 2.4314: Use synthetic lubricant | $498 | $342 |
$498
10,258
kWh
|
- | - | - | - | - | |
05 | 2.1213: Direct warmest air to combustion intake | $1,671 | $1,420 | - |
$1,671
-
MMBtu
|
- | - | - | - | |
06 | 2.2437: Recover waste heat from equipment | $10,274 | $470 | - |
$10,274
-
MMBtu
|
- | - | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,125 | $383 |
$1,125
23,154
kWh
|
- | - | - | - | - | |
08 | 3.5142: Treat and reuse equipment cleaning solutions | $25,000 | $4,530 | - | - | - |
$25,000
-
gal
|
- | - | |
09 | 3.5311: Recover and reuse waste material | $360 | - | - | - | - | - |
$360
-
lb
|
- | |
10 | 3.5316: Contract a wood pallet recycling company | $3,840 | $42 | - | - | - | - |
$3,840
-
lb
|
- | |
11 | 4.521: Clear and rent existing space | $20,300 | $336 | - | - | - | - | - | $20,300 | |
TOTAL RECOMMENDED | $75,195 | $21,723 |
$7,754
159,731
kWh
|
$15,291
-
MMBtu
|
$2,650
-
MMBtu
|
$25,000
-
gal
|
$4,200
-
lb
|
$20,300 | ||
TOTAL IMPLEMENTED | $32,254 | $11,903 |
$7,754
159,731
kWh
|
- | - | - |
$4,200
-
lb
|
$20,300 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Other Gas Savings | Other Liquid (non-haz) Savings | Solid Waste (non-haz) Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs