Assessment Year | 1997 |
---|---|
Principal Product | Turret Steel and Structural Products |
NAICS |
n/a
|
SIC | 3325: Steel Foundries, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 42 |
Plant Area |
135,000
ft2
|
Annual Production | 29,000
ton
|
Production Hrs. Annual | 6,060
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $196,560 | 3,024,619 |
kWh
|
$0.065 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $47,531 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $46,712 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,277 | $420 |
$2,277
34,877
kWh
|
- | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $4,836 | $24,738 |
$4,836
74,443
kWh
|
- | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $259 | $160 |
$259
3,810
kWh
|
- | - | - | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $11,392 | $600 |
$11,392
175,264
kWh
|
- | - | - | |
05 | 2.4314: Use synthetic lubricant | $807 | $360 |
$807
12,309
kWh
|
- | - | - | |
06 | 3.5248: Separate and recycle scrap metal to foundry or for sale | $23,400 | - | - | - | - | $23,400 | |
07 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $560 | $5,000 | - | $(-520.0) | $1,080 | - | |
08 | 4.521: Clear and rent existing space | $4,000 | $1,600 | - | - | $4,000 | - | |
TOTAL RECOMMENDED | $47,531 | $32,878 |
$19,571
300,703
kWh
|
$(-520.0) | $5,080 | $23,400 | ||
TOTAL IMPLEMENTED | $46,712 | $27,718 |
$19,312
296,893
kWh
|
- | $4,000 | $23,400 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs