Assessment Year | 1997 |
---|---|
Principal Product | Petroleum Coke |
NAICS |
n/a
|
SIC | 3624: Carbon and Graphite Products |
Sales Range | $10 M to 50M |
# of Employees | 72 |
Plant Area |
200,000
ft2
|
Annual Production | 440,000
ton
|
Production Hrs. Annual | 8,652
hrs
|
Location (State) | West Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $635,168 | 14,112,837 |
kWh
|
$0.045 |
Natural Gas | $1,005,372 | 402,148 |
MMBtu
|
$2.50 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,467,031 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,874 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $163 | $248 |
$163
3,517
kWh
|
- | - | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $4,350 | $14,800 |
$4,350
96,717
kWh
|
- | - | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $7,241 | $3,680 |
$7,241
160,903
kWh
|
- | - | - | - | |
04 | 2.4314: Use synthetic lubricant | $3,588 | $1,275 |
$3,588
79,719
kWh
|
- | - | - | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,648 | $50 |
$6,648
147,714
kWh
|
- | - | - | - | |
06 | 2.3417: Use waste heat with a closed-cycle gas turbine-generator set to cogenerate electricity and heat | $449,333 | $600,000 |
$484,333
10,764,947
kWh
|
- | $(-35,000.0) | - | - | |
07 | 2.2414: Use waste heat from hot flue gases to preheat | $12,375 | $20,800 | - |
$12,375
-
MMBtu
|
- | - | - | |
08 | 3.5217: Reuse / recycle/ sell paper products | $120 | $100 | - | - | - | - | $120 | |
09 | 4.122: Develop standard procedures to improve internal yields | $983,213 | $100,000 | - | - | - | $983,213 | - | |
TOTAL RECOMMENDED | $1,467,031 | $740,953 |
$506,323
11,253,517
kWh
|
$12,375
-
MMBtu
|
$(-35,000.0) | $983,213 | $120 | ||
TOTAL IMPLEMENTED | $11,874 | $18,828 |
$11,754
261,137
kWh
|
- | - | - | $120 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs