ITAC Assessment: WV0120
ITAC logo
ITAC Assessment: WV0120
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1997
Principal Product Petroleum Coke
NAICS
n/a
SIC 3624: Carbon and Graphite Products
Sales Range $10
M
to 50
M
# of Employees 72
Plant Area 200,000
ft2
Annual Production 440,000
ton
Production Hrs. Annual 8,652
hrs
Location (State) West Virginia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $635,168 14,112,837
kWh
Natural Gas $1,005,372 402,148
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $1,467,031 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,874

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings Primary Raw Material Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $163 $248 $163
3,517
kWh
- - - -
02 2.4133: Use most efficient type of electric motors $4,350 $14,800 $4,350
96,717
kWh
- - - -
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $7,241 $3,680 $7,241
160,903
kWh
- - - -
04 2.4314: Use synthetic lubricant $3,588 $1,275 $3,588
79,719
kWh
- - - -
05 2.4231: Reduce the pressure of compressed air to the minimum required $6,648 $50 $6,648
147,714
kWh
- - - -
06 2.3417: Use waste heat with a closed-cycle gas turbine-generator set to cogenerate electricity and heat $449,333 $600,000 $484,333
10,764,947
kWh
- $(-35,000.0) - -
07 2.2414: Use waste heat from hot flue gases to preheat $12,375 $20,800 - $12,375
-
MMBtu
- - -
08 3.5217: Reuse / recycle/ sell paper products $120 $100 - - - - $120
09 4.122: Develop standard procedures to improve internal yields $983,213 $100,000 - - - $983,213 -
TOTAL RECOMMENDED $1,467,031 $740,953 $506,323
11,253,517
kWh
$12,375
-
MMBtu
$(-35,000.0) $983,213 $120
TOTAL IMPLEMENTED $11,874 $18,828 $11,754
261,137
kWh
- - - $120
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings Primary Raw Material Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs