Assessment Year | 1996 |
---|---|
Principal Product | Air Conditioners and Dehumidifiers |
NAICS |
n/a
|
SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
Sales Range | $10 M to 50M |
# of Employees | 90 |
Plant Area |
120,000
ft2
|
Annual Production | 1,500
pieces
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | Maryland |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $43,344 | 1,649,179 |
kWh
|
$0.026 |
Electricity Demand | $54,461 | 6,248 |
kW-mo/yr
|
$8.72 |
Electricity Fees | $28,677 | - |
|
- |
Natural Gas | $53,218 | 8,380 |
MMBtu
|
$6.35 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,795 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,825 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,942 | $1,562 |
$226
7,913
kWh
|
$1,716
-
kW-mo/yr
|
- | - | - | |
02 | 2.4133: Use most efficient type of electric motors | $151 | $162 |
$15
586
kWh
|
$136
-
kW-mo/yr
|
- | - | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $65 | $35 |
$65
2,345
kWh
|
- | - | - | - | |
04 | 2.7241: Install outside air damper / economizer on hvac unit | $735 | $2,010 |
$735
26,084
kWh
|
- | - | - | - | |
05 | 2.2437: Recover waste heat from equipment | $343 | $522 | - | - |
$343
-
MMBtu
|
- | - | |
06 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,667 | $2,000 | - | - |
$2,667
-
MMBtu
|
- | - | |
07 | 2.1213: Direct warmest air to combustion intake | $1,065 | $3,500 | - | - |
$1,065
-
MMBtu
|
- | - | |
08 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $3,827 | $10,000 |
$(-8.0)
(-293)
kWh
|
- | - | $(-425.0) | $4,260 | |
TOTAL RECOMMENDED | $10,795 | $19,791 |
$1,033
36,635
kWh
|
$1,852
-
kW-mo/yr
|
$4,075
-
MMBtu
|
$(-425.0) | $4,260 | ||
TOTAL IMPLEMENTED | $4,825 | $3,759 |
$306
10,844
kWh
|
$1,852
-
kW-mo/yr
|
$2,667
-
MMBtu
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs