Assessment Year | 1995 |
---|---|
Principal Product | Drawer slides |
NAICS |
n/a
|
SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 40 |
Plant Area |
78,000
ft2
|
Annual Production | 4,261,000
pieces
|
Production Hrs. Annual | 2,125
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $86,852 | 954,865 |
kWh
|
$0.091 |
Natural Gas | $46,870 | 6,308 |
MMBtu
|
$7.43 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $16,659 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,610 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $10,127 | $5,000 | - |
$10,127
-
MMBtu
|
|
02 | 2.2437: Recover waste heat from equipment | $1,755 | $940 |
$1,755
48,945
kWh
|
- | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $483 | - |
$483
13,482
kWh
|
- | |
04 | 2.1213: Direct warmest air to combustion intake | $4,294 | $7,445 | - |
$4,294
-
MMBtu
|
|
TOTAL RECOMMENDED | $16,659 | $13,385 |
$2,238
62,427
kWh
|
$14,421
-
MMBtu
|
||
TOTAL IMPLEMENTED | $10,610 | $5,000 |
$483
13,482
kWh
|
$10,127
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs